- E-Shop
- >
- Electrical Testing
- >
- Multimeters
- >
- FLUKE - 116 Digital HVAC Multimeter
FLUKE - 116 Digital HVAC Multimeter
Maximum voltage between any terminal and earth ground 600 V
Safety IEC 61010-1: Pollution Degree 2
IEC 61010-2-033: CAT III 600V
Display Digital: 6,000 counts, updates 4 per second
Accuracy Specifications
DC millivolts: Range/resolution : 600.0 mV / 0.1 mV. Accuracy: ±([% of reading] + [counts]): 0.5% + 2
DC volts: Range/resolution: 6.000 V / 0.001 V 60.00 V / 0.01 V 600.00 V / 0.1 V
Accuracy: ±([% of reading] + [counts]): 0.5% + 2
Auto volts: Range/resolution: 600.0 V / 0.1 V Accuracy: 2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)
AC millivolts1 True RMS: Range/resolution: 600.0 mV / 0.1 mV Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz)
AC volts1 True RMS: Range/resolution 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V
Accuracy: 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz)
Continuity: Range/resolution: 600 Ω / 1 Ω Accuracy: Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer.
Ohms Range/resolution: 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 600.0 kΩ / 0.1 kΩ 6.000 MΩ / 0.001 MΩ. Accuracy: 0.9% + 1 Range/Resolution: 40.00 MΩ / 0.01 MΩ
Accuracy: 5% + 2
Diode Test: Range/resolution: 2.00 V / 0.001 V Accuracy: 0.9% + 2
Capacitance Range/resolution: 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF / 1 μF 100 μF to 1000 μF. Accuracy: 1.9% + 2 Range/resolution > 1000 μF Accuracy: 5% + 20%
Lo-Z Capacitance: Range 1 nF to 500 μF. Accuracy: 10% + 2 typical
Temperature: (Type-K thermocouple) Range/resolution -40°C to 400°C / 0.1°C Accuracy: 1% + 10² Range/resolution: -40°F to 752°F / 0.2°F Accuracy: 1% + 18²
AC μA true-rms (45 Hz to 500 Hz): Range/resolution: 600.0 μA / 0.1 μA Accuracy: 1.5% + 3
DC μamps: Range/resolution: 600.0 μA / 0.1 μA Accuracy: 1.0% + 2
Hz (V or A input): Range/resolution: 99.99 Hz / 0.01 Hz 999.9 Hz / 0.1 Hz 9.999 kHz / 0.001 Hz 50.00 kHz / 0.01 Hz. Accuracy: 0.1% + 2